2.Cad.No:11/50 06824 ANKARA   Login   Sign Up
PRESSURE GAUGES   THERMOMETERS TEMPERATURE AND PRESSURE SWITCHES   TEST EQUIPMENTS
           
 Home >>Test equipment >>Process Calibrators>>ADT 209-210
ADT 209/210   The new Additel 209 and 210 loop calibrator series combine ease of use and functionality, making them the ideal tools to troubleshoot your process loop. The ADT209 has an accuracy of 0.03% of reading whereas the ADT210 holds an accuracy of 0.01% of reading.
  •       SUMMARY        
  •      SPECIFICATIONS    
  •       ORDER CODE        
  •          PRICE               
  •     DOWNLOADS     
• Accuracy to 0.01% of reading,
• Small and rugged handheld design,
• Measure, source, or simulate loop current,
• Measure DC volts,
• Simultaneously mA and % span display,
• Switch functionality,
• HART 250Ω resistor in series with 24V loop,
• Easy to read display and user interface
 
 
 
 
 
 
 
  Voltage limit 30V between terminals or between terminals and ground
  Display VA LCD display 2.04 x 2.04 in (52 x 52 mm)
  Loop power 24V
  Over-voltage protection 30 V DC
  Overload current protection 33 mA DC
  Vibration/shock Random 2G 5 to 500Hz, 1 meter drop
  Working Altitude <3000 mt.
  Working Environment -10 to 50°C, 95%RH
  Size 163mm x 83mm x 41mm
  Weight 350 gr.
  Power 9V alkaline battery (ANSI/NEDA 1604A or IEC), DC9V DC9V optional adapter available
  Battery life (measure mode) 50 hours
  Calibration Certification NIST-traceable certificate of calibration with data
  Compliance Certification CSA, CE and DNV
  Warranty 3 years
  Electrical Specifications
  Measure  Range Resolution ADT209 Accuracy ADT210 Accuracy
Voltage DC1 0 to 30 V 1mV 0.03%RD+2 mV
0.01%RD+2 mV
Current DC2 0 to 24 mA 1µA 0.03%RD+2 µA 0.01%RD+2 µA
Switch test

Input resistance more than 500Mohm
Trigerlevel: low level <0.3V; high level>2V

(1) 1MOhm input resistance
(2) Loop Transmitter current measure: 700Ohm maximum.
  Source Range
Resolution ADT209 Accuracy
ADT210 Accuracy
Current DC 0 to 24 mA 1µA 0.03%RD+2 µA 0.01%RD+2 µA
Source mode 700Ohm/20 mA maximum
Sink mode External loop voltage nominal 24 V, maximum 30 V, minimum 24 V